6. SERVO MOTOR DRIVING
6 - 45
(2) Detailed setting window
The position data range and unit can be changed with the detailed setting in the point table window. For
the position data range and unit in [Pr. PT01] setting, refer to section 6.2.2. To reflect the setting for the
corresponding parameter, click the "Update Project" button in the point table window.
1)
2)
3)
4)
(a) Selection of control mode (PA01 **STY): 1)
Select either the point table positioning operation or the indexer positioning operation.
(b) Command method selection (PT01 *CTY): 2)
Select either the absolute position command method or the incremental value command method.
(c) Others
1) Feed length multiplication parameter setting STM (PT03 *FTY): 3)
Select a feed length multiplication from 1/10/100/1000.
2) Position data unit setting (PT01 *CTY): 4)
Select a unit of position data from mm/inch/pulse. When pulse is selected for the unit, the setting
of feed length multiplication will be disabled.