4. STARTUP
4 - 4
Set the IP address by using the SLMP command with the rotary switches (SW2/SW3) on the display of the
servo amplifier, MR Configurator2, or a master station (controller). Refer to chapter 7 for IP address
parameters and section 4.3.1 for details of the rotary switches.
Change the IP address with the rotary switches (SW2/SW3) before powering on the servo amplifier.
The IP address can be changed by specifying a MAC address when the SLMP command (IPAddressSet) is
used. Refer to section 3.3 for details on the command.
The IP address you set can be checked in the system configuration window of MR Configurator 2.
The IP address can be set as follows.
Rotary switches (SW2/SW3)
IP address
00h
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 1st octet is "192".
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
When the parameter is set to "_ _0 0", the 2nd octet is "168".
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 3rd octet is "3".
4th octet
The setting value of [Pr. PN12 (_ _ x x)] is used.
01h to FFh
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 1st octet is "192".
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
When the parameter is set to "_ _0 0", the 2nd octet is "168".
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 3rd octet is "3".
4th octet
The setting value of the rotary switches (SW2/SW3) is used.
(4) Parameter setting
POINT
The following encoder cables are of four-wire type. When using any of these
encoder cables, set [Pr. PC04] to "1 _ _ _" to select the four-wire type. Incorrect
setting will result in [AL. 16 Encoder initial communication error 1].
MR-EKCBL30M-L
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Set the parameters according to the structure and specifications of the machine. For details, refer to
chapter 7 of this document and chapter 5 of "MR-J4-_GF_(-RJ) Servo Amplifier Instruction Manual
(Motion Mode)".
After setting the parameters, turn off the power as necessary. Then switch power on again to enable the
parameter values.
(5) Connection with the controller
Set up the controller by following the manual of the controller used.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...