10. OBJECT DICTIONARY
10 - 7
Index
Sub
Index
Name and function
Data
Type
Access
Variable
mapping
Default
Range
Units
EEP-
ROM
Param
eter
2B93
0
Alarm Monitor 19 Load-side encoder information 2
The load-side encoder information 2 at alarm
occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2B97
0
Alarm Monitor 23 Temperature of motor thermistor
The temperature of motor thermistor at alarm
occurrence is returned.
I32 ro
Possible
8000h
to
7FFFh
°C
2B98
0
Alarm Monitor 24 Motor-side cumu. feedback
pulses (before gear)
The cumulative feedback pulses (servo motor-
side unit) at alarm occurrence are returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2BA3
0
Alarm Monitor 35 Motor-side/load-side position
deviation
The motor-side/load-side position deviation at
alarm occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2BA4
0
Alarm Monitor 36 Motor-side/load-side speed
deviation
The servo motor-side/load-side speed deviation
at alarm occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
pulse
2BA5
0
Alarm Monitor 37 Internal temperature of encoder
The internal temperature of encoder at alarm
occurrence is returned.
I32 ro
Possible
8000h
to
7FFFh
°C
2BA6
0
Alarm Monitor 38 Settling time
The settling time at alarm occurrence is returned.
I32 ro
Possible
8000h
to
7FFFh
ms
2BA7
0
Alarm Monitor 39 Oscillation detection frequency
The oscillation detection frequency at alarm
occurrence is returned.
I32 ro
Possible
8000h
to
7FFFh
Hz
2BA8
0
Alarm Monitor 40 Number of tough drive
operations
The number of tough drive operations at alarm
occurrence is returned.
I32 ro
Possible
0000h
to
FFFFh
times
2BAA
0
Alarm Monitor 42 Internal temperature of amplifier
The internal temperature of amplifier at alarm
occurrence is returned.
I32 ro
Possible
8000h
to
7FFFh
°C
2BAD
0
Alarm Monitor 45 Unit power consumption
The unit power consumption at alarm occurrence
is returned.
I32 ro
Possible
8000h
to
7FFFh
W
2BAE
0
Alarm Monitor 46 Unit total power consumption
The unit total power consumption at alarm
occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
Wh
2BAF
0
Alarm Monitor 47 Current position
The current position at alarm occurrence is
returned. In the indexer method, the value is fixed
to 0.
I32 ro
Possible 80000000h
to
7FFFFFFFh
2BB0
0
Alarm Monitor 48 Command position
The command position at alarm occurrence is
returned. In the indexer method, the value is fixed
to 0.
I32 ro
Possible 80000000h
to
7FFFFFFFh
2BB1
0
Alarm Monitor 49 Command remaining distance
The command remaining distance at alarm
occurrence is returned.
I32 ro
Possible 80000000h
to
7FFFFFFFh
2BB2
0
Alarm Monitor 50 Point table No./Station position
No.
Point table No. or station position No. at alarm
occurrence is returned.
I32 ro
Possible
0000h
to
00FFh
2C18
0
Power ON cumulative time
The cumulative time after power on of the servo
amplifier is returned.
U32 ro
Impossible
0 00000000h
to
FFFFFFFFh
hour
2C19
0
Number of inrush relay on/off times
The number of on/off times of the inrush relay of
the servo amplifier is returned.
U32 ro
Impossible
0 00000000h
to
FFFFFFFFh
times
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...