9. MANUFACTURER FUNCTIONS
9 - 30
9.5.10 Cam No. setting method
POINT
When the cam No. is set to a value other than "0" to "8", [AL. F6.5 Cam No.
external error] occurs. If the cam data of a specified cam No. does not exist, [AL.
F6.3 Cam unregistered error] occurs. At this time, the cam control is not
executed and the servo motor does not start. Turning off the cam control
command clears [AL. F6.3] and [AL. F6.5].
The cam No. can be set and changed with Target CAM No. (2D80h) in the same method as setting with
[Cam control data No. 49] or selecting the point table No.
The priority level of cam control parameter and Target CAM No. (2D80h) is as follows.
[Pr. PT35] setting
[Cam control
data No. 49]
setting
2D80h Setting
_ 0 _ _
(Simple cam function
disabling setting)
The cam function is disabled with the setting of [Pr. PT35].
_ 1 _ _
(Simple cam function
enabling setting)
"0" (initial
value)
The cam No. is set with Target CAM No. (2D80h).
Other than "0"
The cam No. is set with [Cam control data No. 49]. The cam
No. set with Target CAM No. (2D80h) is disabled.
: Enable, : Disable
9.5.11 Stop operation of cam control
If one of the following stop causes occurs on the output axis during cam control, the cam control stops after
the output axis is stopped. (Bit 5 of Status DO2 (2D12h) turns off.)
To restart the cam control, adjust the synchronous position of the output axis.
Stop cause
Command stop processing
Remark
Software stroke limit detection
Instantaneous stop
Refer to (1) in this section.
Stroke limit detection
Instantaneous stop
Refer to (1) in this section.
Stop due to forced stop 1 or 2, or alarm
occurrence
Instantaneous stop or
deceleration to a stop
Stop due to base circuit shut-off. Refer to (1) in this
section.
Stop by the forced stop deceleration function. Refer to
(2) in this section.
Bit 5 of Control DI2 (2D02h) is off.
Instantaneous stop
Refer to (1) in this section.
Servo-off
Instantaneous stop
Coasting state
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...