9. MANUFACTURER FUNCTIONS
9 - 32
9.5.12 Restart operation of cam control
When the cam control is stopped during operation, a gap may be generated in the synchronous position
relationship between the main shaft and the driven shaft. To solve the gap, return the main shaft and the
driven shaft to the synchronization starting point and then start the synchronous operation.
Point table No.
Forward
rotation
0 r/min
Reverse
rotation
Command speed
Forward
rotation
0 r/min
Reverse
rotation
Command speed
ON
OFF
Servo-on
ON
OFF
ON
OFF
ON
OFF
Controlword bit 4
(New set-point)
Command position
Command position
«Driven shaft»
Controlword bit 4
(New set-point)
Control DI 2 bit 5
Cam axis one cycle
current value
Cam axis feed current value
Status DO 2 bit 5
«Main shaft/driven shaft»
«Main shaft»
5 ms or longer
3 ms or shorter
Point table No. 1
(Note 1)
If the cam control stops during
operation, the synchronous
position relationship with the main
shaft is broken.
Positioning to the synchronization
start position (Feed current value
0 (= Command position 0))
Point table in which the command
position 0 is set as the target
position
Positioning to the synchronization
start position (Command
position 0)
1
2
3 ms or shorter
Point table No. 1
(Note 1)
(Note 1)
(Note 1)
5 ms or
shorter
The above shows an example for when the synchronization starting point is the point where both command
position and feed current value are "0".
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...