5. CiA 402 DRIVE PROFILE
5 - 4
(2) Statusword (6041h)
Index
Sub
Index
Access Name
Data
Type
Default
6041h 0
ro Statusword
U16
The current control status can be checked.
The following table lists the bits of this object. The status can be checked with bit 0 to bit 7.
Bit Symbol
Description
0
RTSO
Ready To Switch On
1 SO
Switched
On
2 OE
Operation
Enabled
3 F
Fault
4 VE
Voltage-enabled
0: The bus voltage is lower than the certain (RA) level.
1: The bus voltage is equal to or higher than the certain level.
5 QS
Quick stop
0: During a quick stop
1: Not during a quick stop (including in the test mode)
6
SOD
Switch On Disabled
7 W
Warning
0: No warning has occurred.
1: A warning is occurring.
8
Reserved
The value at reading is undefined.
9 RM
Reserved
The value at reading is undefined.
10 TR
Target reached
Differs depending on Modes of operation (6060h). (Refer to chapter 6.)
11 ILA
Internal limit active
0: The forward rotation stroke end, reverse rotation stroke end, and software position limit have
not been reached.
1: The forward rotation stroke end, reverse rotation stroke end, or software position limit has been
reached (Enabled in the pt, idx, jg, or hm mode).
12 to 13
OMS
Operation Mode Specific
Differs depending on Modes of operation (6060h). (Refer to chapter 6.)
14 to 15
Reserved
The value at reading is undefined.
The following table lists the servo amplifier statuses that can be read with bit 0 to bit 7.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3 Bit
2 Bit
1 Bit
0
Status
0
0
0
0
0
Not ready to switch on
1 0 0 0 0
Switch
on
disable
0 1 0 0 0 1
Ready
to
switch
on
0 1 0 0 1 1
Switch
on
0 1 0 1 1 1
Operation
enabled
0 0 0 1 1 1
Quick
stop
active
0 1 1 1 1
Fault
reaction
active
0 1 0 0 0
Fault
1
Main power on (power input on)
1
Warning
(warning
occurrence)
Bit 11 turns on when the stroke limit, software limit, or positioning command is outside the range.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...