9. MANUFACTURER FUNCTIONS
9 - 10
9.5.6 Setting list
(1) List of items set with MR Configurator2
Set the following on the cam setting window of MR Configurator2.
Setting item
Setting
Cam
control
data
Main shaft input
axis selection
Select a command input method for the cam axis.
Select "synchronous encoder axis" or "servo input axis".
Cam No.
selection
Select the number to create the cam control data.
Resolution
setting
Set the cam resolution. Select from 256/512/1024/2048.
Cam axis length
per cycle
Set a travel distance of cam one cycle. Command unit is used as an input unit.
Cam stroke
amount
Set a cam stroke amount for the stroke ratio of 100% when using the stroke ratio data type cam
control.
Cam data
Create the cam data on the cam creating window of MR Configurator2. After the data is created, write
the cam data to the servo amplifier.
(2) List of items set with parameters of the servo amplifier
Set the following with the parameters of the servo amplifier.
Setting item
Setting
Operation mode selection
Select "Positioning mode (point table method)" with [Pr. PA01 Operation mode].
Cam function setting
Enable the cam function with [Pr. PT35 Function selection T-5].
Cam data selection
Select the cam data to be executed with Target CAM No. (2D80h).
[Cam control data No. 49 - Cam No.] can also be used for selecting the cam data for execution.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...