2. CC-Link IE FIELD NETWORK BASIC PROTOCOL
2 - 2
2.3 Link device
In cyclic communication, communication data of the request message and response message is read as
object data (RWwn, RWrn, RYn, and RXn) of the servo amplifier. Table 2.1 and 2.2 list initial settings.
Table 2.1 RYn/RXn mapping (pt/idx/jg/hm)
Master station
→
Servo amplifier (RYn)
Servo amplifier
→
Master station (RXn)
Device No.
(Note)
Device Symbol
Remark
Device
No.
(Note)
Device Symbol
Remark
RYn0 to RY
(n + 3) E
Unavailable
RXn0 to RX
(n + 3) E
Unavailable
RY (n + 3) F
Cyclic communication ready
command
CSR
RX (n + 3) F Cyclic communication ready
SSR
Note. "n" depends on the station No. setting.
Table 2.2 RWwn/RWrn mapping (pt/idx/jg/hm)
Master station
→
Servo amplifier (RWwn)
Servo amplifier
→
Master station (RWrn)
Device No.
(Note)
Index Device
Device No.
(Note)
Index Device
RWwn00
6060
Modes of operation
RWrn00
6061
Modes of operation display
RWwn01 6040 Controlword
RWrn01 6041 Statusword
RWwn02
2D01
Control DI 1
RWrn02
6064
Position actual value
RWwn03
2D02
Control DI 2
RWrn03
RWwn04
2D03
Control DI 3
RWrn04
606C
Velocity actual value
RWwn05
2D60
Target point table
RWrn05
RWwn06
6081 Profile
velocity
RWrn06
60F4
Following error actual value
RWwn07
RWrn07
RWwn08
6083 Profile
acceleration
RWrn08
6077
Torque actual value
RWwn09
RWrn09
2D11
Status DO 1
RWwn0A
6084 Profile
deceleration
RWrn0A
2D12
Status DO 2
RWwn0B
RWrn0B
2D13
Status DO 3
RWwn0C
60B8
Touch probe function
RWrn0C
2D15
Status DO 5
RWwn0D
2DD1
Target speed No.
RWrn0D
2D17
Status DO 7
RWwn0E
RWrn0E
2D68
Point Demand value
RWwn0F
RWrn0F
2D69
Point actual value
RWwn10
RWrn10
RWwn11
RWrn11
2A42
Current alarm 2
RWwn12
RWrn12
60B9
Touch probe status
RWwn13
RWrn13
60BA
Touch probe pos1 pos value
RWwn14
RWrn14
RWwn15
RWrn15
60BB
Touch probe pos1 neg value
RWwn16
RWrn16
RWwn17
RWrn17
RWwn18
RWrn18
RWwn19
RWrn19
RWwn1A
RWrn1A
RWwn1B
RWrn1B
RWwn1C
RWrn1C
RWwn1D
RWrn1D
RWwn1E
RWrn1E
RWwn1F
RWrn1F
Note. "n" depends on the station No. setting.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...