10. OBJECT DICTIONARY
10 - 10
Index
Sub
Index
Name and function
Data
Type
Access
Variable
mapping
Default
Range
Units
EEP-
ROM
Param
eter
2D01
to
2D0A
0
Control DI 1 to Control DI 10
The on/off status of input device can be read. The
on/off status of input device can also be set.
U16 rw
Possible 0
0000h
to
FFFFh
2D11
to
2D1A
0
Status DO 1 to Status DO 10
The on/off status of output device can be read.
U16 ro
Possible
0000h
to
FFFFh
2D20
0
Velocity limit value
The speed limit value is set.
U32 rw
Possible
50000 00000000h
to
instantaneous
permissible
speed
0.01
r/min
0.01
mm/s
PT52
2D28
0
Motor rated speed
The servo motor rated speed is returned.
U32 ro
Impossible
00000000h
to
FFFFFFFFh
r/min
mm/s
2D35 0 Encoder
status
The number of entries is returned.
U8 ro
Impossible
1 01h
(fixed)
1 Encoder
status1
The encoder status is returned.
Bit 0: Whether the servo amplifier is used in an
absolute position detection system or not is
returned.
0 = Incremental system
1 = Absolute position detection system
Bit 1 to Bit 31: Reserved
U32 ro
Impossible
00000000h
to
00000001h
2 Encoder
status2
The status of the scale measurement encoder is
returned.
Bit 0: Whether the servo amplifier is used in an
absolute position detection system or not is
returned.
0 = Incremental system
1 = Absolute position detection system
Bit 1: Whether the scale measurement function is
enabled or disabled is returned.
0 = Disabled
1 = Enabled
Bit 2: Whether the connected scale measurement
encoder is the absolute position type or not is
returned.
0 = Incremental type
1 = Absolute position type
Bit 3 to Bit 31: Reserved
U32 ro
Impossible
00000000h to
00000111h
2D42
0
Max ABS counter
The maximum value of the multi-revolution
counter is displayed.
U32 ro
Impossible
00000000h
to
FFFFFFFFh
rev
2D50
0
One-touch tuning mode
Setting "1" to "3" starts one-touch tuning. After
one-touch tuning is completed, the setting value
automatically changes to "0".
1: Basic setting
2: High setting
3: Low setting
U8 rw
Impossible
0
00h to 03h
2D51 0 One-touch
tuning status
The one-touch tuning progress is returned.
I8 ro
Impossible
0
00h to 64h
%
2D52
0
One-touch tuning Stop
Writing "1EA5h" can stop one-touch tuning. Any
value other than "1EA5h" is invalid.
U16 wo
Impossible
0000h/
1EA5h
2D53
0
One-touch tuning Clear
The parameter changed in one-touch tuning can
be returned to the value before the change. The
description of the setting values is as follows.
0000: Restores the default value
0001: Restores the value before one-touch tuning.
U16 wo
Impossible
0000h
to
0001h
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...