9. MANUFACTURER FUNCTIONS
9 - 39
(3) Cam axis feed current value restoration
POINT
When the restored cam axis feed current value differs from the feed current
value at cam control switching, the cam axis feed current value moves to the
value restored just after the cam control switching.
If the difference between the restored cam axis feed current value and the feed
current value is larger than the value set in [Pr. PA10 In-position range], [AL.
F6.2 Cam axis feed current value restoration failed] occurs, and the control
cannot be switched to the cam control. Note that increasing the value of the in-
position range may lead to a rapid cam switching.
When the cam axis position restoration target is set to "Cam axis feed current value restoration", and
then bit 5 of Control DI2 (2D02h) turns on, the control is switched to the cam control, restoring the "Cam
axis feed current value" based on the "Cam axis current value per cycle" and the "Cam standard
position".
Set the "Cam axis current value per cycle" and "Cam standard position" used for the restoration with
cam control data.
Cam axis one cycle current value
Cam axis feed current value
Cam standard position