9. MANUFACTURER FUNCTIONS
9 - 14
3) Cam data start position
This setting is available only for the stroke ratio data type cam data.
The cam data position where the "cam axis current value per cycle" becomes "0" can be set as
the cam data start position.
The initial value of the cam data start position is "0". The cam axis is controlled with the cam data
from the 0th point (stroke ratio = 0%).
When a value other than "0" is set as the cam data start position, cam control is started from the
point where the stroke ratio is not 0%.
Set the cam data start position for each cam data within the setting range of "0 to (Cam resolution
- 1)".
t
t
Cam standard
position
(First cycle)
Cam standard
position
(Second cycle)
Cam standard
position
(Third cycle)
Feed current value
Cam axis
one cycle current value
Zeroth point
Last point
Cam data
start position
4) Timing of applying cam control data
New values are applied to "Cam No." and "Cam stroke amount" when bit 5 of Control DI2
(2D02h) turns on.
"Cam standard position" is updated when Cam axis current value per cycle passes through the
0th point of the cam data.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...