9. MANUFACTURER FUNCTIONS
9 - 20
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
pt idx
6
*CIBSS
Cam
standard
position initial
setting value
This is enabled when [Cam control data No. 3] is set to "1". Set the initial value of
the cam standard position in the output axis position unit.
The unit will be changed to [µm], 10
-4
[inch], or [pulse] with the setting of [Pr. PT01].
Setting range: -999999 to 999999
0
Refer to
Function
column
for unit.
7
*CICYS
Cam axis
current value
per cycle
initial setting
value
Set the position to start the search processing to restore the cam axis current value
per cycle. Set this item when restoring the position of the return path with the to-and-
fro control cam pattern.
When [Cam control data No. 30] is set to "1"
The unit will be changed to [
μ
m], 10
-4
[inch], or [pulse] with the setting of [Pr. PT01].
When [Cam control data No. 30] is set to "2"
The unit will be changed to [
μ
m], 10
-4
[inch], 10
-3
[degree], or [pulse] with the
setting of [Cam control data No. 14].
Setting range: 0 to [Cam control data No. 48] - 1
0
Refer to
Function
column
for unit.
14
*ETYP
Synchronous
encoder axis
unit
_ _ _ x Control unit
0: mm
1: inch
2: degree
3: pulse
0h
_ _ x _ Feed length multiplication
0: × 1
1: × 10
2: × 100
3: × 1000
This digit is disabled when [Cam control data No. 14] is set to "_ _ _ 2" or "_ _ _ 3".
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...