7. PARAMETERS
7 - 30
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
P
S
PN22
**IPOAA
Operation
specification
IP address A
_ _ x x Operation specification IP address 2
Set the 2nd octet of the IP address of the network device allowed to be connected in
hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
x x _ _ Operation specification IP address 1
Set the 1st octet of the IP address of the network device allowed to be connected in
hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
PN23
**IPOAB
Operation
specification
IP address B
_ _ x x Operation specification IP address 4
Set the 4th octet of the IP address of the network device allowed to be connected in
hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
x x _ _ Operation specification IP address 3
Set the 3rd octet of the IP address of the network device allowed to be connected in
hexadecimal.
When both [Pr. PN22] and [Pr. PN23] are set to "0000h", the function is disabled.
When the function is enabled, the servo amplifier allows the following data 1) to 3) to be
imported only if the IP address of the master station (external device) matches with the
operation specification IP address. If they are mismatched, the data is discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Setting range: 00h to FFh
00h
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...