10. OBJECT DICTIONARY
10 - 33
10.4 Detail object dictionary (in the 6000s)
POINT
This section describes the objects in the 6000s. Refer to section 10.1 for details
on the objects not listed here.
10.4.1 Quick stop option code (605Ah)
Index
Sub
Index
Name Data
Type
Access
605Ah
0
Quick stop option code
I16
rw
The operation method of deceleration to a stop can be specified. The following table shows the supported
methods and the operations.
Setting
value
Description
1
For manufacturer setting
2
In the homing mode (hm), point table mode (pt), Jog mode (jg), and indexer mode (idx), the servo motor decelerates to a
stop with Quick stop deceleration (6085h), and the state shifts to the Switch On Disabled.
3 to 8
For manufacturer setting
10.4.2 Halt option code (605Dh)
When Halt Bit (Bit 8 of Controlword) is set to 1, the servo motor decelerates to a stop with the deceleration
time constant of Homing acceleration (609Ah), Profile deceleration (6084h), or the point table according to
the setting of Halt option code (605Dh). This function can be used in the homing mode (hm) and point table
method (pt/jg). Operation in other modes can be performed regardless of the Halt Bit status. When Halt Bit is
set to 0 at deceleration stop operation, the servo motor decelerates to a stop and returns to the operable
state.
(1) Object list
Index
Sub
Index
Name Data
Type
Access
605Dh
0
Halt option code
I16
rw
The following table shows descriptions of Halt option code (605Dh).
Setting
value
Description
1
jg: The servo motor decelerates to a stop with Profile deceleration (6084h), and the state does not change from Operation
Enabled (servo-on).
hm: The servo motor decelerates to a stop with Homing acceleration (609Ah), and the state does not change from
Operation Enabled (servo-on).
pt: The servo motor decelerates to a stop with the deceleration time constant set in the point tables, and the state does not
change from Operation Enabled (servo-on).
2 to 4
For manufacturer setting
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...