7. PARAMETERS
7 - 26
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
C
P
P
S
PT69
ZSTH
Home
position shift
distance
(extension
parameter)
Set the extension parameter of [Pr. PT07].
When [Pr. PT69] is used, the home position shift distance is calculated as follows.
Home position shift distance = [Pr. PT07] + ([Pr. PT69] × 65536)
The unit will be as follows depending on the positioning mode.
In the point table method
The unit can be changed to [µm], 10
-4
[inch], or [pulse] with the setting of [Pr. PT01].
In the indexer method
It will be command unit [pulse]. (A load-side rotation expressed by the number of servo
motor resolution pulses)
Refer to the Function column of [Pr. PA10] for the command unit. Additionally, when a
value equal to or more than "1001" is set, the value will be clamped to "1000".
Setting range: 0 to 32767
0
Refer to
Function
column
for unit.
PT71
DCTH
Travel
distance after
proximity dog
(extension
parameter)
Set the extension parameter of [Pr. PT09].
When [Pr. PT71] is used, the travel distance after proximity dog is calculated as follows.
Travel distance after proximity dog = [Pr. PT09] + ([Pr. PT71] × 65536)
The unit can be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], or [pulse] with the setting of [Pr.
PT01].
Setting range: 0 to 32767
0
Refer to
Function
column
for unit.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...