6. SERVO MOTOR DRIVING
6 - 42
Index Sub
Name
Data
Type
Access Default
Description
2D60h
Target point table
I16
rw
0
Point table command
0: Not operate
1 to 255: Execute the specified point table
-1: High-speed home position return
2D68h
Point demand value
I16
ro
Point table demand
The currently specified point table No. is
returned.
While the servo motor is stopped, the value
becomes the setting value of the Target point
table (2D60h).
2D69h
Point actual value
I16
ro
Current point table
The completed point table is returned.
2801h
to
28FFh
0
Point table 001 to 255
U8
ro
7
Number of entries
Point table
1 Point
data I32
rw
Position data
Unit: pos units
2 Speed I32
rw
Speed
Unit: 0.01 r/min or 0.01 mm/s
3 Acceleration I32
rw
Acceleration time constant
Unit: ms
4 Deceleration I32
rw
Deceleration time constant
Unit: ms
5 Dwell I32
rw
Dwell
Unit: ms
6 Auxiliary I32
rw
Auxiliary
function
2A43h
0
Point table error
U8
ro
2
Number of entries
Point table error
1
Point table error No.
I32
ro
Point table error No.
2
Point table error
factor
I32 ro
Point table error factor
The error status is indicated when this bit is
turned on.
Refer to chapter 10.
(2) Details on the OMS bit of Controlword (pt mode)
Bit Symbol
Description
4 New
set-point
The operation starts from the point table specified with the Target point table (2D60h) when
the Bit turns on.
5 Direction
Specify the servo motor rotation direction. If the direction of the rotation is reversed while the
servo motor is rotating, the servo motor once stops and then starts rotating in the opposite
direction.
The operations are performed when [Pr. PT01] is set to "_ _ _ 1 (incremental value
command method)".
0: Forward rotation direction
1: Reverse rotation direction
6
(reserved)
The value at reading is undefined. Set "0" when writing.
8 HALT
0: Positioning is executed.
1: The servo motor stops according to Halt option code (605Dh).
9
(reserved)
The value at reading is undefined. Set "0" when writing.
Содержание MR-J4-_GF
Страница 26: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 3 2 4 Mapping data details of link device Refer to chapter 10 ...
Страница 27: ...2 CC Link IE FIELD NETWORK BASIC PROTOCOL 2 4 MEMO ...
Страница 185: ...8 TROUBLESHOOTING AT POWER ON 8 2 MEMO ...
Страница 227: ...9 MANUFACTURER FUNCTIONS 9 42 MEMO ...
Страница 269: ...10 OBJECT DICTIONARY 10 42 MEMO ...
Страница 271: ...MEMO ...