11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 25
11.10 Earth-leakage current breaker
(1) Selection method
High-frequency chopper currents controlled by pulse width modulation flow in the AC servo circuits.
Leakage currents containing harmonic contents are larger than those of the motor which is run with a
commercial power supply.
Select an earth-leakage current breaker according to the following formula, and ground the servo
amplifier, servo motor, etc. securely.
To minimize leakage currents, make the input and output cables as short as possible, and make the
grounding cable longer than 30 cm.
Rated sensitivity current
10 • {Ig1 + Ign + Iga + K • (Ig2 + Igm)} [mA]············································· (11.1)
Earth-leakage current breaker
Type
Mitsubishi
products
K
Models provided with
harmonic and surge
reduction techniques
NV-SP
NV-SW
NV-CP
NV-CW
NV-HW
1
Ign
Noise filter
Cable
Ig1
Iga
Ig2
Igm
M
Servo
amplifier
NV
Cable
General models
BV-C1
NFB
NV-L
3
Ig1: Leakage current on the electric channel from the earth-leakage current breaker to the input
terminals of the servo amplifier (Found from Fig. 11.2.)
Ig2: Leakage current on the electric channel from the output terminals of the servo amplifier to the servo
motor (found from Fig. 11.2.)
Ign: Leakage current when a filter is connected to the input side (4.4 mA per one FR-BIF)
Iga: Leakage current of the servo amplifier (Found from table 11.3.)
Igm: Leakage current of the servo motor (Found from table 11.2.)
Leakage current [mA]
Cable size [mm
2
]
120
100
80
60
40
20
0
2
5.5 14
3.5 8
38100
22
30
60150
80
Fig. 11.2 Example of leakage current per km (lg1, lg2) for CV cable run in metal conduit
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...