4. STARTUP
4 - 36
(4) Motor-less operation
Without connecting the servo motor, output signals or status display can be provided in response to the
input device as if the servo motor is actually running. This operation can be used to check the sequence
of a controller or the like.
(a) Start of motor-less operation
After setting "_ _ _ 1" in [Pr. PC60], cycle the power. After that, perform external operation as in
ordinary operation.
(b) Termination of motor-less operation
To terminate the motor-less operation, set [Pr. PC60] to "_ _ _ 0" and then turn the power off.
(5) Program operation
Positioning operation can be performed in two or more operation patterns combined, without using a
controller. Use this operation with the forced stop reset. This operation may be used independently of
whether servo-on or servo-off and whether a controller is connected or not.
Exercise control on the program operation screen of MR Configurator2. For full information, refer to the
MR Configurator2 Installation Guide.
Operation
Screen control
Start
Click the "Operation start" button.
Stop
Click the "Stop" button.
Forced stop
Click the "Forced Stop" button.
(6) Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. This function is used for
output signal wiring check, etc. Exercise control on the DO forced output screen of MR Configurator2.
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...