8. TROUBLESHOOTING
8 - 1
8. TROUBLESHOOTING
POINT
As soon as an alarm occurs, turn SON (Servo-on) off and interrupt the power.
8.1 Alarm and warning list
When an error occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to section 8.2 or 8.3 and take the appropriate action. When an alarm occurs,
ALM will turn off.
To output alarm codes, set [Pr. PD34] to "_ _ _ 1". Alarm codes are outputted by on/off of bit 0 to bit 2.
Warnings ([AL. 91] to [AL. F3]) do not have alarm codes. The alarm codes in the following table will be
outputted when they occur. The alarm codes will not be outputted in normal condition.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
ż
in the
alarm deactivation column. Warnings are automatically canceled after the cause of occurrence is removed.
For the alarms and warnings in which "SD" is written in the stop method column, the servo motor stops with
the dynamic brake after forced stop deceleration. For the alarms and warnings written "DB" in the stop
method column, the servo motor stops with the dynamic brake without forced stop deceleration.
Table 8.1 Alarm list
Alarm code
Alarm deactivation
No.
CN1
49
(Bit 2)
CN1
23
(Bit 1)
CN1
24
(Bit 0)
Name
Detailed
display
Detail name
Stop
method
(Note 2,
3)
Alarm
reset
(RES)
Press
the
"SET"
button
on the
current
alarm
screen.
Power
off to
On
(Note 4)
10.1
Voltage drop in the power
DB
10
0
1
0
Undervoltage
10.2
Bus voltage drop
SD
12.1
RAM error 1
DB
Alarm
12.2
RAM error 2
DB
12
0
0
0
Memory error 1 (RAM)
12.4
RAM error 4
DB
12.5
RAM error 5
DB
13.1
Clock error 1
DB
13
0
0
0
Clock error
13.2
Clock error 2
DB
14.1
Control process error 1
DB
14.2
Control process error 2
DB
14.3
Control process error 3
DB
14.4
Control process error 4
DB
14.5
Control process error 5
DB
14
0
0
0
Control process error
14.6
Control process error 6
DB
14.7
Control process error 7
DB
14.8
Control process error 8
DB
14.9
Control process error 9
DB
14.A
Control process error 10
DB
15.1
EEP-ROM error at power on
DB
15
0
0
0
Memory error 2
(EEP-ROM)
15.2
EEP-ROM error during operation
DB
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...