11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 4
11.2 Regenerative option
CAUTION
Do not use servo amplifiers with regenerative options other than the combinations
specified below.
Otherwise, it may cause a fire.
11.2.1 Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Regenerative power [W]
Servo
amplifier
Built-in
regenerative
resistor
MR-RB032
[40
ȍ
]
MR-RB12
[40
ȍ
]
MR-RB30
[13
ȍ
]
MR-RB32
[40
ȍ
]
(Note)
MR-RB50
[13
ȍ
]
MR-JE-10A
30
MR-JE-20A
30
100
MR-JE-40A
10
30
100
MR-JE-70A
20
30
100
300
MR-JE-100A
20
30
100
300
MR-JE-200A
100
300
500
MR-JE-300A
100
300
500
Note. Always install a cooling fan.