8. TROUBLESHOOTING
8 - 10
Alarm No.: 17
Name: Board error
Alarm content
A part in the servo amplifier is malfunctioning.
Display Detail name
Cause
Check method
Check result
Action
17.1 Board error 1
(1) A current detection
circuit is malfunctioning.
It occurs.
Replace the servo
amplifier.
Check if the alarm
occurs during the servo-
on status.
It does not occur.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take countermeasures
against its cause.
17.3 Board error 2
Check it with the check method for [AL. 17.1].
17.4 Board error 3
(1)
It is repeatable.
Replace the servo
amplifier.
The servo amplifier
recognition signal was
not read properly.
Disconnect the cables
except the power supply,
and then check the
repeatability.
It is not repeatable.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take countermeasures
against its cause.
Alarm No.: 19
Name: Memory error 3 (FLASH-ROM)
Alarm content
A part (Flash-ROM) in the servo amplifier is failure.
Display Detail name
Cause
Check method
Check result
Action
19.1 FLASH-ROM
error 1
(1) The Flash-ROM is
malfunctioning.
It is repeatable.
Replace the servo
amplifier.
Disconnect the cables
except the power supply,
and then check the
repeatability.
It is not repeatable.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take countermeasures
against its cause.
19.2 FLASH-ROM
error 2
Check it with the check method for [AL. 19.1].
Alarm No.: 1A
Name: Servo motor combination error
Alarm content
The combination of servo amplifier and servo motor is incorrect.
Display Detail name
Cause
Check method
Check result
Action
1A.1
(1)
The combination is
incorrect.
Use them in the correct
combination.
Servo motor
combination
error
The servo amplifier and
the servo motor was
connected incorrectly.
Check the model name
of the servo motor and
corresponding servo
amplifier.
The combination is
correct.
Check (2).
(2) An encoder is
malfunctioning.
Replace the servo motor,
and then check the
repeatability.
It is not repeatable.
Replace the servo motor.
Alarm No.: 1E
Name: Encoder initial communication error 2
Alarm content
An encoder is malfunctioning.
Display Detail name
Cause
Check method
Check result
Action
1E.1
(1)
It is not repeatable.
Replace the servo motor.
Encoder
malfunction
An encoder is
malfunctioning.
Replace the servo motor,
and then check the
repeatability.
It is repeatable.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take countermeasures
against its cause.
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...