3. SIGNALS AND WIRING
3 - 33
(Note) Input device
Enabled torque limit value
TL1
TL
Limit value status
CCW power running/CW
regeneration
CW power running/CCW
regeneration
0
0
Pr. PA11
Pr .PA12
TLA
>
Pr. PA11
Pr. PA12
Pr. PA11
Pr. PA12
0
1
TLA
<
Pr. PA11
Pr. PA12
TLA
TLA
Pr. PC35
>
Pr. PA11
Pr. PA12
Pr. PA11
Pr. PA12
1
0
Pr. PC35
<
Pr. PA11
Pr. PA12
Pr. PC35
Pr. PC35
TLA
>
Pr. PC35
Pr. PC35
Pr. PC35
1
1
TLA
<
Pr. PC35
TLA
TLA
Note. 0: Off
1: On
(c) TLC (Limiting torque)
TLC turns on when the servo motor torque reaches the torque limited using the forward rotation
torque limit, reverse rotation torque limit or analog torque limit.