8. TROUBLESHOOTING
8 - 11
Alarm No.: 1F
Name: Encoder initial communication error 3
Alarm content
The connected encoder is not compatible with the servo amplifier.
Display Detail name
Cause
Check method
Check result
Action
1F.1 Incompatible
encoder
(1)
Check the model of the
servo motor.
It is not compatible with
the amplifier.
Replace it with the servo
motor which is
compatible.
A servo motor, which is
not compatible with the
servo amplifier, was
connected.
It is compatible with the
amplifier.
Check (2).
(2) The software version of
the servo amplifier does
not support the servo
motor.
Check if the software
version supports the
servo motor.
It is not supported.
Replace the servo
amplifier to one which
software version
supports the servo
motor.
It is supported.
Check (3).
(3)
It is not repeatable.
Replace the servo motor.
An encoder is
malfunctioning.
Replace the servo motor,
and then check the
repeatability.
It is repeatable.
Replace the servo
amplifier.
Alarm No.: 20
Name: Encoder normal communication error 1
Alarm content
An error occurred in the communication between an encoder and servo amplifier.
Display Detail name
Cause
Check method
Check result
Action
20.1
(1) An encoder cable is
malfunctioning.
It has a failure.
Repair or replace the
cable.
Check if the encoder
cable is disconnected or
shorted.
It has no failure.
Check (2).
Encoder normal
communication -
Receive data
error 1
(2) The servo amplifier is
malfunctioning.
It is not repeatable.
Replace the servo
amplifier.
Replace the servo
amplifier, and then check
the repeatability.
It is repeatable.
Check (3).
(3)
It is not repeatable.
Replace the servo motor.
An encoder is
malfunctioning.
Replace the servo motor,
and then check the
repeatability.
It is repeatable.
Check (4).
(4) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take countermeasures
against its cause.
20.2 Encoder normal
communication -
Receive data
error 2
Check it with the check method for [AL. 20.1].
20.3 Encoder normal
communication -
Receive data
error 3
20.5 Encoder normal
communication -
Transmission
data error 1
20.6 Encoder normal
communication -
Transmission
data error 2
20.7 Encoder normal
communication -
Transmission
data error 3
20.9 Encoder normal
communication -
Receive data
error 4
20.A Encoder normal
communication -
Receive data
error 5
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...