APPENDIX
App. - 11
(2) Setting
The servo amplifier is factory-set to output the servo motor speed to MO1 (Analog monitor 1) and the
torque to MO2 (Analog monitor 2). The setting can be changed as listed below by setting the [Pr. PC14]
and [Pr. PC15] value.
Refer to (3) for the detection point.
Setting
value
Output item
Description
Setting
value
Output item
Description
00
Servo motor speed
Maximum speed
CW direction
CCW direction
Maximum speed
0
8 [V]
-8 [V]
01
Torque
Maximum torque
Power running in
CW direction
Power running in
CCW direction
Maximum torque
0
8 [V]
-8 [V]
02
Servo motor speed
Maximum speed
CW direction
CCW direction
Maximum speed 0
8 [V]
03
Torque
Maximum torque
Power running in
CW direction
Power running in
CCW direction
Maximum torque 0
8 [V]
04
Current command
Maximum current
command
(Maximum torque
command)
CW direction
CCW direction
Maximum current
command
(Maximum torque
command)
0
8 [V]
-8 [V]
05
The command pulse
frequency (±10 V/±4
Mpulses/s)
4 [Mpulse/s]
CW direction
CCW direction
4 [Mpulse/s]
0
10 [V]
-10 [V]
06
Servo motor-side droop
pulses
(Note 1, 2, 3)
(±10 V/100 pulses)
100 [pulse]
CW direction
CCW direction
100 [pulse]
0
10 [V]
-10 [V]
07
Servo motor-side droop
pulses
(Note 1, 2, 3)
(±10 V/1000 pulses)
1000 [pulse]
CW direction
CCW direction
1000 [pulse]
0
10 [V]
-10 [V]
08
Servo motor-side droop
pulses
(Note 1, 2, 3)
(±10 V/10000 pulses)
10000 [pulse]
CW direction
CCW direction
10000 [pulse]
0
10 [V]
-10 [V]
09
Servo motor-side droop
pulses
(Note 1, 2, 3)
(±10 V/100000 pulses)
100000 [pulse]
CW direction
CCW direction
100000 [pulse]
0
10 [V]
-10 [V]
0D
Bus voltage
400 [V]
0
8 [V]
0E
Speed command 2
(Note 2)
Maximum speed
CW direction
CCW direction
Maximum speed
0
8 [V]
-8 [V]
17
Encoder inside
temperature (±10
V/±128
˚
C)
128 [°C]
-128 [°C]
0
10 [V]
-10 [V]
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...