6. NORMAL GAIN ADJUSTMENT
6 - 12
(d) If an error occurs
Check the error cause referring table 6.2 of (1) (d) of this section.
2 s interval
Error code
If an error occurs during the one-touch tuning, the tuning will be forcibly terminated and the
stop symbol and error code from "C 001" to "C 00F" will be displayed by turns with 2 s
interval.
Stop symbol
Initial screen
Pushing the "SET" button will switch to the initial screen.
(e) If an alarm occurs
If an alarm occurs during tuning, one-touch tuning will be forcibly terminated and the alarm
No. will be displayed.
One-touch tuning in progress
Alarm display
(f) If a warning occurs
If a warning occurs during tuning, the alarm No. of the warning will be displayed.
When the warning is one which continue the motor driving, the one-touch tuning will be
continued.
One-touch tuning in progress
Alarm display (warning)