6. NORMAL GAIN ADJUSTMENT
6 - 4
(2) When you use push buttons
Make one-touch tuning as follows.
Startup a system referring to chapter 4.
Rotate the servo motor by an external controller, etc. (The one-touch tuning cannot be performed if the
servo motor is not operating.)
Select the initial screen ("AUTO") of the one-touch tuning with the "MODE" button during motor
driving. Push the "SET" button for 2 s or more during displaying "AUTO" to switch to the response
mode selection ("AUTO."). Push the "MODE" and "SET" buttons at the same time for 3 s or more to
switch to the response mode selection ("AUTO.") without going through the initial screen of the one-
touch tuning ("AUTO").
The initial value of response mode is "AUTO." (basic mode). As necessary, push the "UP" or "DOWN"
button to select "AUTO.H" (high mode) or "AUTO.L" (low mode).
Start
Startup of the system
Operation
One-touch tuning start
Response mode selection
One-touch tuning execution
End
Push the "SET" button to start one-touch tuning. Push the "SET" button during servo motor driving.
When one-touch tuning is completed normally, the parameters described in table 6.1 will be set
automatically.
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...