3. SIGNALS AND WIRING
3 - 28
(3) Output signal
Control
mode
Device
Symbol
Connector
pin No.
Function and application
I/O
division
P S
T
Encoder A-
phase pulse
(differential line
driver)
LA
LAR
CN1-4
CN1-5
DO-2
Encoder B-
phase pulse
(differential line
driver)
LB
LBR
CN1-6
CN1-7
These devices output pulses of encoder output pulse set in [Pr. PA15] in
the differential line driver type.
In CCW rotation of the servo motor, the encoder B-phase pulse lags the
encoder A-phase pulse by a phase angle of
ʌ
/2.
The relation between rotation direction and phase difference of the A-
phase and B-phase pulses can be changed with [Pr. PC19].
Encoder Z-
phase pulse
(differential line
driver)
LZ
LZR
CN1-8
CN1-9
The encoder zero-point signal is outputted in the differential line driver
type. One pulse is outputted per servo motor revolution. This turns on
when the zero-point position is reached. (negative logic)
The minimum pulse width is about 400
ȝ
s. For home position return using
this pulse, set the creep speed to 100 r/min. or less.
DO-2
Encoder Z-
phase pulse
(open-collector)
OP
CN1-33 The encoder zero-point signal is outputted in the open-collector type.
DO-2
Analog monitor 1
MO1
CN1-26 This is used to output the data set in [Pr. PC14] to between MO1 and LG in
terms of voltage.
Resolution: 10 bits or equivalent
Analog
output
Analog monitor 2
MO2
CN1-29 This signal outputs the data set in [Pr. PC15] to between MO2 and LG in
terms of voltage.
Resolution: 10 bits or equivalent
Analog
output
(4) Power supply
Control
mode
Device
Symbol
Connector
pin No.
Function and application
I/O
division
P S
T
Digital I/F power
supply input
DICOM CN1-20
CN1-21
Input 24 V DC (24 V DC ± 10% 300 mA) for I/O interface. The power
supply capacity changes depending on the number of I/O interface points
to be used.
For sink interface, c of 24 V DC external power supply.
For source interface, connect - of 24 V DC external power supply.
Open-collector
sink interface
power supply
input
OPC
CN1-12 When inputting a pulse train in the open-collector type with sink interface,
supply this terminal with the positive (+) power of 24 V DC.
Digital I/F
common
DOCOM CN1-46
CN1-47
Common terminal of input signal such as EM2 of the servo amplifier. This
is separated from LG.
For sink interface, connect - of 24 V DC external power supply.
For source interface, c of 24 V DC external power supply.
Control common
LG
CN1-3
CN1-28
CN1-30
CN1-34
This is a common terminal for TLA, TC, VC, VLA, OP, MO1, and MO2.
Pins are connected internally.
Shield
SD
Plate
Connect the external conductor of the shielded wire.
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...