8. TROUBLESHOOTING
8 - 27
Alarm No.: F2
Name: Drive recorder - Miswriting warning
Alarm content
A waveform measured by the drive recorder function was not recorded.
Display Detail name
Cause
Check method
Check result
Action
F2.1 Drive recorder -
Area writing
time-out
warning
(1) The Flash-ROM is
malfunctioning.
Disconnect the cables
except the power supply,
and then check the
repeatability.
It is repeatable.
Replace the servo
amplifier.
F2.2 Drive recorder -
Data miswriting
warning
(1) Data were not written to
the drive recorder area.
Check if the records
have all written.
They have all written.
Delete the records in the
drive recorder window of
MR Configurator2.
If records cannot be
written after deletion,
replace the servo
amplifier.
Alarm No.: F3
Name: Oscillation detection warning
Alarm content
[AL. 54 Oscillation detection] may occur.
Display Detail name
Cause
Check method
Check result
Action
F3.1 Oscillation
detection
warning
Check it with the check method for [AL. 54.1].
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...