5. PARAMETERS
5 - 35
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
PC36
*DMD
Status display
selection
_ _ x x Status display selection at power-on
This is used to select a status display shown at power-on.
00: Cumulative feedback pulses
01: Servo motor speed
02: Droop pulses
03: Cumulative command pulses
04: Command pulse frequency
05: Analog speed command voltage (Note 1)
06: Analog torque command voltage (Note 2)
07: Regenerative load ratio
08: Effective load ratio
09: Peak load ratio
0A: Instantaneous torque
0B: Within one-revolution position (1 pulse unit)
0C: Within one-revolution position (100 pulses unit)
0D: ABS counter (Note 3)
0E: Load to motor inertia ratio
0F: Bus voltage
10: Encoder inside temperature
11: Settling time
12: Oscillation detection frequency
13: Number of tough operations
14: Unit power consumption (increment of 1 W)
15: Unit power consumption (increment of 1 kW)
16: Unit total power consumption (increment of 1 Wh)
17: Unit total power consumption (increment of 100 kWh)
00h
Note 1. It is for the speed control mode. It will be the analog speed limit voltage in
the torque control mode.
2. It is for the torque control mode. It will be the analog torque limit voltage in
the speed control mode and position control mode.
3. Travel distance from power on is displayed by counter value.
_ x _ _ Status display at power-on in corresponding control mode
0: Depends on the control mode
0h
Control mode
Status display at power-on
Position
Cumulative feedback pulses
Position/speed Cumulative feedback pulses/servo motor speed
Speed
Servo motor speed
Speed/torque
Servo motor speed/analog torque command
voltage
Torque
Analog torque command voltage
Torque/position Analog torque command voltage/cumulative
feedback pulses
1: Depends on the last two digit setting of the parameter
x _ _ _ For manufacturer setting
0h
Содержание MELSERVO-JE MR-JE-100A
Страница 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Страница 29: ...2 INSTALLATION 2 6 MEMO ...
Страница 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Страница 171: ...5 PARAMETERS 5 44 MEMO ...
Страница 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Страница 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Страница 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Страница 254: ...9 DIMENSIONS 9 5 2 SCR connector system 3M Receptacle 36210 0100PL Shell kit 36310 3200 008 Unit mm 34 8 39 5 22 4 11 0 ...
Страница 255: ...9 DIMENSIONS 9 6 MEMO ...
Страница 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...