7.4.5 Leakage current and apparent power measurement
Notes:
Ì
If any of the earth bond resistance tests, insulation resistance tests, or substitute
leakage current tests fail in autotest sequence, the leakage current measurement
will be prohibited from operating!
Ì
Consider the displayed warnings before starting or proceeding with
measurements!
The autotest sequence stops when the leakage current measurement is performed and
a prompt will appear on the screen.
The following actions can be taken to continue or complete autotest sequence:
START...................... Start the leakage current measurement.
Proceed with the next leakage current measurement (in
continuous measurement mode only).
Proceed to the next autotest sequence measurement (in single measurement mode
only).
F2 function key...........View leakage current test help screens.
F3 function key ......... Repeat the leakage current measurement.
ENTER key............... Proceed to the next autotest sequence measurement (in
continuous measurement mode only).
F4 function key ......... Skip leakage current measurement.
F5 function key ......... End the autotest sequence.
7.4.6 Touch leakage current measurement
Notes:
Ì
If any of the earth bond resistance tests, insulation resistance tests, substitute
leakage current test or leakage current test fail or were skipped in selected
autotest sequence, the touch leakage current measurement will be prohibited!
Ì
When measuring touch leakage current on appliances, the earth bond test probe
must be used (see section
6.5 Touch leakage current
)!
Ì
Consider the warnings on the display before starting measurement!
The autotest sequence stops after performing a touch leakage current measurement.
The following actions can be taken to continue or complete autotest sequence:
START...................... Start the touch leakage current measurement.
Proceed with the next touch leakage current measurement (in
continuous measurement mode only).
Proceed to the next autotest sequence measurement (in single
measurement mode only).
F2 function key...........View touch leakage test help screens.
F3 function key ......... Repeat the touch leakage current measurement.
ENTER key............... Proceed to the next autotest sequence measurement (in
continuous measurement mode only).
F4 function key ......... Skip touch leakage current measurement.
F5 function key ......... End the autotest sequence.