7.3.3 Compare of results (evaluation of result trends)
If an autotest sequence was performed from the Project autotests menu, an additional
option TREND is offered in the
View result
menu after the autotest is finished.
View Project autotest results menu
In the Save results window, press the F4 (VIEW) key the results to enter the view
results window. By pressing the F4 button again (TREND) a comparison between the
old and new test data will be performed. This is a very useful feature to evaluate result
trends in cases where results are relatively close to the limit.
Compare results menu example
Meaning of trend symbols:
Ç
New result of particular test is better than last result.
Examples: New insulation resistance result is higher.than old result.
New earth bond result is lower than old one.
{
Difference between old and new result of particular test is so small that can be
treated as the same.
Example: New insulation resistance result stays at the same level as old result.
È
New result of particular test is worse than last result.
Examples: New insulation resistance result is lower than old result.
New earth bond result is higher than old one.
By using F1 and F2 function keys all measurements can be compared. Use F5 key to
return to
View result menu
.