OmegaPATPlus / BetaPATPlus
Working with autotest results
61
By using F2 function key in the actual parameter line, parameter value can be reset to
last accepted value. The new parameter value is accepted when the cursor is set to
another parameter line.
When 2
nd
tag manipulation is enabled in the
Setup menu
, the 2
nd
appliance number
and its name can be added or removed from the actual autotest results by pressing F5
function key. For the second appliance, only its name can be edited. For detailed
description refer to chapter
9.3.6 Instrument settings
.
UK model
In the
Appliance no.
field up to 10 numeric characters can be entered. The
Appliance
number
can also be scanned with a barcode reader.
In the
Test site
,
Location
and
Appliance name
fields, up to 15 alpha-numeric or
special characters can be entered. Names can also be selected from the list of 100
predefined names for each parameter.
In
Retest period
field, at the most 2 numeric characters can be entered to represent the
number of months between retest.
In
Repairing code
field, up to 20 alpha-numeric or special characters can be entered.
In the
Comments
field, up to 25 alpha-numeric or special characters can be entered.
By using the F2 function key in the actual parameter line, parameter value can be reset
to the last accepted value. The new parameter value is accepted when the cursor is set
to another parameter line.
All parameters added to the autotest results have, in general, a possibility to be
replicated or default set to blank when saving new autotest results. Appliance number
can also be automatically incremented when new autotest sequence is finished.
In
Aus / NZ model
, the 2
nd
appliance number and its name can also be added to the
actual autotest results by pressing F5 function key. In this case, the 2
nd
tag manipulation
has to be enabled in
Setup
menu. For detailed description refer to chapter
9.3.6
Instrument settings
.
Once the information regarding the appliance has been set, the results can be saved to
the flash memory of the instrument by pressing the F1 function key. Once the data has
been saved, the machine emits two short beeps and the instrument returns to
Autotest
menu.
Notes:
Ì
The date and time are automatically attached to the saved results.
Ì
The autotest results cannot be stored if the
Appliance no.
field is empty.
Ì
User
field cannot be edited (this must be selected from the main menu of the
instrument).
8.2 Recalling
results
Select
Recall/delete/send memory
in
Main menu
by using
¿
and
À
cursor keys and
press ENTER key to confirm.
Search results
menu is displayed.