Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0523
User Response
No action; information only.
•
81070208-0a01ffff : Sensor [SensorElementName] has transitioned to a less severe state from
critical. (PS 1 Therm Fault)
This message is for the use case when an implementation has detected a Sensor transition to less
severe from critical.
May also be shown as 810702080a01ffff or 0x810702080a01ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix:
PLAT
ID:
0523
User Response
No action; information only.
•
81070208-0a02ffff : Sensor [SensorElementName] has transitioned to a less severe state from
critical. (PS 2 Therm Fault)
This message is for the use case when an implementation has detected a Sensor transition to less
severe from critical.
May also be shown as 810702080a02ffff or 0x810702080a02ffff
Severity
Info
Serviceable
No
Automatically notify support
784
Lenovo System x3650 M4 Installation and Service Guide
Содержание x3650 M4 BD 5466
Страница 1: ...Lenovo System x3650 M4 Installation and Service Guide Machine Type 7915 ...
Страница 6: ...iv Lenovo System x3650 M4 Installation and Service Guide ...
Страница 176: ...164 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 226: ...214 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1042: ...1030 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1200: ...1188 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1204: ...1192 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1211: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1199 ...
Страница 1212: ...Taiwan BSMI RoHS declaration 1200 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1221: ......
Страница 1222: ......