Table 21. Light path diagnostics panel LEDs (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by "(trained technician only)," that step must be performed only by a trained
technician.
LED
Description
Action
PCI
An error has occurred on a PCI
card, a PCI bus, or on the system
board. An additional LED is lit
next to a failing PCI slot.
1. Check the riser-card LEDs, the ServeRAID error LED, and
the dual-port network adapter error LED to identify the
component that caused the error.
2. Check the system-error log for information about the error.
3. If you cannot isolate the failing component by using the
LEDs and the information in the system-error log, remove
one component at a time; and restart the server after each
component is removed.
4. Replace the following components, in the order shown,
restarting the server each time:
• PCI riser cards
• ServeRAID adapter
• Optional network adapter
• (Trained technician only) System board
5. If the failure remains, go to
http://www.ibm.com/support/entry/portal/docdisplay?
lndocid=SERV-CALL.
NMI
A nonmaskable interrupt has
occurred, or the NMI button was
pressed.
1. Check the system-error log for information about the error.
2. Restart the server.
PS An invalid power
configuration error has occurred.
If the CONFIG LED and the PS LED are lit, the system issues
an invalid power configuration error. Make sure that both
power supplies installed in the server are of the same rating
or wattage.
CPU A hardware
configuration error has occurred.
If the CONFIG LED and the CPU LED are lit, complete the
following steps to correct the problem:
1. Check the microprocessors that were just installed to
make sure that they are compatible with each other (see
“Replacing a microprocessor and heat sink” on page
330 for additional information about microprocessor
requirements).
2. (Trained technician only) Replace the incompatible
microprocessor.
3. Check the system-error logs for information about the
error. Replace any component that is identified in the error
log.
CONFIG
MEM A hardware
configuration error has occurred.
If the CONFIG LED and the MEM LED are lit, check the
system-event log in the Setup utility or IMM2 error messages.
Follow steps indicated in Appendix B “UEFI/POST diagnostic
codes” on page 1007 and Appendix A “Integrated management
module II (IMM2) error messages” on page 345.
LINK
Reserved.
176
Lenovo System x3650 M4 Installation and Service Guide
Содержание x3650 M4 BD 5466
Страница 1: ...Lenovo System x3650 M4 Installation and Service Guide Machine Type 7915 ...
Страница 6: ...iv Lenovo System x3650 M4 Installation and Service Guide ...
Страница 176: ...164 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 226: ...214 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1042: ...1030 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1200: ...1188 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1204: ...1192 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1211: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1199 ...
Страница 1212: ...Taiwan BSMI RoHS declaration 1200 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1221: ......
Страница 1222: ......