Step 8.
If you are instructed to return the adapter, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Replacing an adapter
Use this information to replace an adapter.
The following notes describe the types of adapters that the server supports and other information that
you must consider when you install an adapter:
• Locate the documentation that comes with the adapter and follow those instructions in addition to
the instructions in this section.
• The server provides one internal SAS/SATA RAID connector and two PCI slots on the system board.
See “System-board optional-device connectors” on page 32 for the location of the internal SAS/SATA
RAID connector and riser-card slots. You can replace the ServeRAID SAS/SATA adapter with an
optional ServeRAID SAS/SATA adapter in the slot. For configuration information, see the ServeRAID
documentation at http://www.lenovo.com/support.
• Do not set the maximum digital video adapter resolution above 1600 x 1200 at 75 Hz for an LCD monitor.
This is the highest resolution that is supported for any add-on video adapter that you install in the server.
• Read the following table before installing memory modules when any NVIDIA Quadro adapters is installed.
Table 37. NVIDIA Quadro video adapter configurations
Description
Supported maximum total memory size
Quadro 600 adapter
128 GB
Quadro 2000 adapter
512 GB
Quadro 4000 adapter
512 GB
Quadro 6000 adapter
512 GB
• Any high-definition video-out connector or stereo connector on any add-on video adapter is not supported
• The server does not support legacy 5V PCI adapters.
• When you install any PCI adapter, the power cords must be disconnected from the power source before
you remove the PCI Express riser-card assembly and the PCI-X riser-card assembly. Otherwise, the
active power management event signal will be disabled by the system-board logic, and the Wake on LAN
feature might not work. However, after the server is powered-on locally, the active power manager active
power management event signal will be enabled by the system-board logic.
• The server provides two PCI riser-card slots on the system board. If you want to install a PCI Express or
PCI-X adapter, you must order the PCI riser-card option.
• If you are installing a ServeRAID-M5110, ServeRAID-M5120, or an LLM-SM dual port 10GbE SFP+
adapter, it can only be installed in PCI slot 1, 2, 4, or 5.
• Before you install an additional adapter, go to Table 2 “Power supply configurations” on page 9 for
detailed power supply configurations.
The following illustration shows the locations of the adapter expansion slots from the rear of the server.
Maximal card dimension supported in each slot (rear view)
1
Full height , up to full length
4
Full height , up to full length
2
Full height, half length
5
Full height , up to full length
3
Full height, half length
6
Full height, half length
(Riser 1)
(Riser 2)
282
Lenovo System x3650 M4 Installation and Service Guide
Содержание x3650 M4 BD 5466
Страница 1: ...Lenovo System x3650 M4 Installation and Service Guide Machine Type 7915 ...
Страница 6: ...iv Lenovo System x3650 M4 Installation and Service Guide ...
Страница 176: ...164 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 226: ...214 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1042: ...1030 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1200: ...1188 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1204: ...1192 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1211: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1199 ...
Страница 1212: ...Taiwan BSMI RoHS declaration 1200 Lenovo System x3650 M4 Installation and Service Guide ...
Страница 1221: ......
Страница 1222: ......