Figure 133. 2.5-inch hot-swap hard disk drive backplane installation
Step 7.
Connect the SAS signal and power/configuration cables to the backplane and the system board.
See “2.5-inch hard disk drive cable connection” on page 112 for details.
Step 8.
Replace the fan cage and fans if you removed them (see “Replacing the fan cage assembly” on
page 136 and “Replacing a hot-swap fan” on page 138).
Step 9.
Reinstall the hard disk drives (see “Replacing a hot-swap hard disk drive” on page 126).
Step 10. Install the top cover (see “Replacing the top cover” on page 118).
Step 11. Slide the server into the rack.
Step 12. Reconnect the power cords and any cables that you removed.
Step 13. Turn on the peripheral devices and the server.
Removing the 3.5-inch hot-swap hard disk drive backplane
Use this information to remove the 3.5-inch hot-swap hard disk drive backplane.
To remove the 3.5-inch hot-swap hard disk drive backplane, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v and “Removing and replacing
guidelines” on page 101.
Step 2.
Turn off the server and peripheral devices and disconnect all power cords.
Step 3.
Remove the top cover (see “Removing the top cover” on page 116).
Step 4.
Pull the hard disk drives or fillers out of the server slightly to disengage them from the backplane.
See “Removing a hot-swap hard disk drive” on page 125.
Step 5.
To obtain more working room, remove the fan cage assembly (see “Removing the fan cage
assembly” on page 135).
Step 6.
Disconnect the SAS signal and power/configuration cables from the system board.
Note:
Disengage all latches, release tabs or locks on cable connectors when you disconnect all
cables from the system board. Failing to release them before removing the cables will damage
186
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide
Содержание HX3510-G
Страница 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Страница 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1229: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1217 ...
Страница 1230: ...Taiwan BSMI RoHS declaration 1218 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1239: ......
Страница 1240: ......