Air baffle
Figure 47. Air baffle removal
To remove the air baffle, complete the following steps:
Step 1.
Read the safety information that begins on page “Safety” on page v and “Removing and replacing
guidelines” on page 101.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables
(see “Turning off the server” on page 31).
Step 3.
Remove the top cover (see “Removing the top cover” on page 116).
Step 4.
Remove PCI riser-card assemblies, if needed (see “Removing a riser-card assembly” on page 143).
Step 5.
Place your fingers under the back of the top of the air baffle; then, lift the air baffle out of the server.
Attention:
For proper cooling and airflow, replace the air baffle before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Step 6.
If you are instructed to return the air baffle, follow all of the packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Replacing the air baffle
Use this information to replace the air baffle.
To replace the air baffle, complete the following steps:
Step 1.
Read the safety information that begins on page “Safety” on page v and “Removing and replacing
guidelines” on page 101.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the top cover (see “Removing the top cover” on page 116).
Step 4.
Align the air baffle tabs with the baffle slots on both sides of the chassis; then, lower the air baffle
into the server. Press the air baffle down until it is securely seated.
120
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide
Содержание HX3510-G
Страница 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Страница 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1229: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1217 ...
Страница 1230: ...Taiwan BSMI RoHS declaration 1218 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1239: ......
Страница 1240: ......