Table 16. The maximal card dimension supported in each slot
Riser-card assembly
Slot
number
The maximal card dimension supported
1
Double height, up to full length
Riser-card assembly 1
3
Full height, half length
4
Low-profile
5
Low-profile
6
Double height, up to full length
Riser-card assembly 2
8
Full height, half length
The following notes describe the types of adapters that the server supports and other information that
you must consider when you install an adapter:
• Locate the documentation that comes with the adapter and follow those instructions in addition to
the instructions in this section.
• The server provides two internal SAS connectors and two SAS/SATA RAID riser-card slots on the system
board. See “System-board optional-device connectors” on page 25 for the location of the internal
SAS/SATA RAID connector and riser-card slots.
• Do not set the maximum digital video adapter resolution above 1600 x 1200 at 75 Hz for an LCD monitor.
This is the highest resolution that is supported for any add-on video adapter that you install in the server.
• Read the following table before installing memory modules when any NVIDIA adapters is installed.
Table 17. NVIDIA video adapter configurations
Description
Supported maximum total memory size
NVIDIA Tesla K8, K40c, and M60 (Active)
1 TB
• Do not install the following adapters in the slot 3 and the slot 8.
Table 18. Non-supported adapters in the slot 3 and the slot 8
Adapter description
Option part number
FRU part number
N2215 SAS/SATA HBA for System x
47C8675
47C8676
N2215 SAS/SATA HBA for System x
00AE912
00AE914
Intel x520 Dual Port 10GbE SFP+
Adapter for System x
49Y7960
49Y7962
• Any high-definition video-out connector or stereo connector on any add-on video adapter is not
supported.
• When you install any PCI adapter, the power cords must be disconnected from the power source before
you remove the PCI Express riser-card assembly. Otherwise, the active power management event signal
will be disabled by the system-board logic, and the Wake on LAN feature might not work. However, after
the server is powered-on locally, the active power manager active power management event signal will
be enabled by the system-board logic.
To replace an adapter, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v and “Removing and replacing
guidelines” on page 101.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the server top cover (see “Removing the top cover” on page 116).
.
Removing, and replacing components
153
Содержание HX3510-G
Страница 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Страница 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1229: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1217 ...
Страница 1230: ...Taiwan BSMI RoHS declaration 1218 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Страница 1239: ......
Страница 1240: ......