![Larsen & Toubro C*2000 Series Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/larsen-and-toubro/c-2000-series/c-2000-series_user-manual_676507086.webp)
Chapter 7 Basic Functions
7-5
Cx2000 AC Drive
Setting of keypad potentiometer V2+ terminal AI (dial J1 to V terminal)
Group
Code
Item
Set value Range
Initial Unit
Drive group
0.00
Target frequency
-
0.00 ~ 400.00 0.00
Hz
Frq
Frequency setting mode
6
0 ~ 8
0
Set Frq code of Drive group to 6.
Relevant parameters: I 2 ~ I 5 ,I 6 ~ I 10
Please refer to the method and example for setting frequency through keypad potentiometer V2+
terminal AI 0 ~ 20mA (dial J1 to terminal I).
Frequency setting via RS-485 communication
Group
Code Item
Set value Range
Initial Unit
Drive group 0.00
Target frequency
-
0.00~ 400.00 0.00
Hz
Frq
Mode of frequency setting
7
0 ~ 8
0
Set Frq code of Drive group to 7.
Relevant parameters: I 59,I 60,I 61.
Refer to Chapter 11. Communication Function
Frequency setting via digital potentiometer (up-down)
Group
Code
Item
Set value Range
Initial Unit
Drive group 0.00
Target frequency
-
0.00~ 400.00 0.00
Hz
Frq
Frequency setting mode
8
0 ~ 8
0
Set Freq. code of Drive group to 8.
Relevant parameters: I 17 ~ I 21
Refer to Up-Down Function in Chapter 8. Application Function.
Содержание C*2000 Series