![Larsen & Toubro C*2000 Series Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/larsen-and-toubro/c-2000-series/c-2000-series_user-manual_676507076.webp)
Chapter 5 – Parameter list
5-31
Cx2000 AC Drive
Input/output group
LED
display
Address for
communica
tion
Parameter
name
Range
Description
Factory
defaults
Adj.
During
run
Page
I77
144D
Write
address
register 4
0
~
42239
The user can register up to 8
discontinuous addresses and write
them all with one Write command
8
0
11-6
I78
144E
Write
address
register 5
5
I79
144F
Write
address
register 6
6
I80
1450
Write
address
register 7
7
I81
1451
Write
address
register 8
8
I82
1)
1452
Brake open
current
0.0
~
180.0
[%]
Sets current level to open the brake.
It is set according to H33‟s (motor
rated current) size
50.0
O
8-26
I83
1453
Brake open
delay time
0.00
~
10.00[sec]
Sets Brake open delay time.
1.00
X
I84
1454
Brake open
FX
frequency
0.00
~
400.00
[Hz]
Sets FX frequency to open the brake
1.00
X
I85
1455
Brake
open RX
frequency
0.00
~
400.00
[Hz]
Sets RX frequency to open the brake
1.00
X
I86
1456
Brake
close delay
time
0.00
~
10.00[sec]
Sets delay time to close the brake
1.00
X
I87
1457
Brake
close
frequency
0.00
~
400.00
[Hz]
Sets frequency to close the brake
2.00
X
1)
:
It is indicated when choosing I54~I55 as a 19 (Brake signal).
Содержание C*2000 Series
Страница 163: ......