Chapter 4 Parameter setting
4-9
Cx2000 AC Drive
Parameter setting in Function group
When changing the parameter value of F28 from 2 to 5
FU group 1
1
-. The 1
st
code F 0 of Function group 1 is displayed.
-. Press the ENT key.
2
-. 1 (F1 code) is displayed
-. 8 is set by pressing the Up (
) key.
3
-. 8 is displayed.
-. Press the Left (
) key once so that the cursor is moved for one digit to
the left.
4
-. 0 is active.
-. 2 is set by pressing the Up
5
-. Means the current location is for No. 28 parameter of Function group 1.
-. Press the ENT key.
6
-. F28 is displayed.
-. Press the ENT key.
7
-. Present value of F28 is set to 2.
-. Increase the value to 5 by pressing Up (
) key.
8
-. Press the ENT key.
9
-. Parameter number will appear after 5 is blinking. Parameter change is
complete.
-. Press either Left (
) or Right (
) keys.
10
-. Moving to first code of Function group 1 is complete.
♣
The above is also applied to parameter setting in function group 2 and I/O group.
Содержание C*2000 Series