Chapter 5 – Parameter list
5-23
Cx2000 AC Drive
Input/output group
LED
display
Address for
comm
Parameter
name
Range
Description
Factory
defaults
Adj.
During
run
Page
I 0
1400
Jump code 0
~
87 Sets the code number to jump.
1
O
4-5
I 1
1401
V2 input wave
filtering time
constant
0
~
9999
Set panel potentiometer V2 input filtering
wave time constant
10
O
7-2
I 2
1402
V2 input Min
voltage
0.00
~
5.00[V]
Sets Min. voltage of V2 input.
0.00
O
I 3
1403
V2 input Min
voltage
corresponding
frequency
0.00
~
400.00
[Hz]
Sets the inverter output min. frequency at
min. voltage of panel potentiometer input.
0.00
O
I 4
1404
V2 input
Max voltage]
0.00
~
5.00[V]
Sets the maximum voltage of panel
potentiometer V2.
5.00
O
I 5
1405
V2 input Max.
voltage
corresponding
frequency
0.00
~
400.00
[Hz]
Sets the panel potentiometer V2 Max.
input voltage, corresponding frequency.
60.00
O
I 6
1406
Filter time
constant for
V1 input
0
~
9999
Sets simulation input A1 (terminal V) input
filtering wave time constant.
10
O
7-2
I 7
1407
V1 input Min
voltage
0.00
~
10.00[V]
Sets the minimum voltage of the V1 Input.
0.00
O
I 8
1408
V1 input Min
voltage
corresponding
frequency
0.00
~
400.00
[Hz]
Sets simulation input A1 (terminal V) min.
input voltage, corresponding frequency.
0.00
O
I 9
1409
V1 input Max
voltage
0.00
~
10.00[V]
Sets simulation input A1 (terminal V) Max.
input voltage.
10.00
O
I10
140A
V1 input Max.
voltage
corresponding
frequency
0.00
~
400.00
[Hz]
Sets simulation input A1 (Terminal V) Max.
input voltage, corresponding frequency.
60.00
O
Содержание C*2000 Series