![Larsen & Toubro C*2000 Series Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/larsen-and-toubro/c-2000-series/c-2000-series_user-manual_676507142.webp)
Chapter 9 Monitoring
9-7
Cx2000 AC Drive
Select the desired item to be output via the keypad of relay.
I56: When 17 (Fault output) is selected in I55, Multi-function output terminal and relay will be activated with
the value in I56.
0 : FDT-1
Check whether the output frequency matches the user-setting frequency.
Active condition: Absolute value (preset frequency - output frequency) <= Frequency Detection Bandwidth/2
Group
Code
Name
Set Value
Range
Initial
Unit
I/O Group
I53
Detected Frequency
Bandwidth
-
0.00~ 400.00 10.00
Hz
Cannot be set above Max frequency (F21).
When setting I53 to 10.0:
1 : FDT-2
Activated when the preset frequency matches frequency detection level (I52) and FDT-1 condition is met.
Active condition: (Preset frequency = FDT level) & FDT-1
Group
Code
Name
Set Value Range
Default
Unit
I/O Group
I52
Detected Frequency
level
-
0.00 ~
400.00
30.00
Hz
I53
Detected Frequency
Bandwidth
-
10.00
Cannot be set above Max frequency (F21).
15Hz
Freq. setting
Freq.
MO
20Hz
20Hz
40Hz
35Hz
Run Command
40Hz
Содержание C*2000 Series
Страница 163: ......