Chapter 8 Application
8-21
Cx2000 AC Drive
8.14 2
nd
motor operation
Group
Code
Item
Set
Value
Setting Range Initial
Unit
Function
group 2
H81
2nd motor accel time
-
0.0 ~ 6000.0
5.0
Second
H82
2nd motor decel time
-
0.0 ~ 6000.0
10.0
Second
H83
2nd motor base freq.
-
30.00~ 400.00 60.00
Hz
H84
2nd motor V/F pattern
-
0 ~ 2
0
H85
2nd motor Positive torque boost
-
0 ~ 15
5
%
H86
2nd motor Negative torque boost -
0 ~ 15
5
%
H87
2nd motor stall prevention level
-
30 ~ 150
150
%
H88
2nd motor electronic thermal
level for 1 min
-
50 ~ 200
150
%
H89
2nd motor electronic thermal
level for continuous operation
-
50 ~ 150
100
%
H90
2nd motor rated current
-
0.1~ 100.0
26.3
A
I/O Group
I17
Multi-function Input terminal
P1Function select
-
0 ~ 27
0
~
~
I21
Multi-function Input terminal
P5Function select
12
4
Set the terminal among Multi-function input terminals (P1~ P5) for second motor operation.
To define the terminal P5 as second motor operation, set I21 to 12 in the I/O group.
Used when an inverter operates 2 motors connected to two different types of the loads.
2nd motor operation does not drive 2 motors at the same time.
As the figure below, when using two motors with an inverter by exchanging them, select one motor
from 2 motors connected. When 1
st
selected motor operation is stopped, select a terminal for 2nd motor
and define H81-H90 parameters to drive the 2nd motor.
Define the 2nd motor select when a motor is stopped.
H81 ~ H90 parameters function the same as 1
st
motor.
Cx2000
P5