264
Nexam Pro User Manual
Appendix C
Message
Cause
Posible actions to
resolve
DT-XX transducer not connected to CO2 module Transducer expected but not
connected
Contact your LABORIE
representative
Due to a change in the channel configuration
some approved events might have been set to
not approved. It is advised to re-analyse these
events
Events problem
Re-analyse events
Error during backup [Filename]
N/A
Contact your LABORIE
representative
Error during saving test data!
General error during saving test
data
Contact your LABORIE
representative
Error during saving test data! Investigation
number > 99
Investigation number > 99
Contact your LABORIE
representative
Error during saving test data! Not enough
memory available. Cannot perform
investigation.
Not enough memory available
Contact your LABORIE
representative
Error in writing to file: [Filename]
Error during save to demo file
Retry save as demo file
Error while allocating MPEG4 buffers!
MPEG4 buffer problem
Contact your LABORIE
representative
Error while allocating video buffers. Increase the
non-paged memory size in Milconfig.
Error while allocating video
buffers
Increase the non-paged
memory size in
Milconfig
Fatal error during reading of the testdata!
Exception during reading test data Contact your LABORIE
representative
Fatal error occurred during the measurement!
Exception during measurement
Contact your LABORIE
representative
Flowmeter not connected!
Module expected but not
connected
Contact your LABORIE
representative
Flowmeter not connected! The LABORIE-bus
devices can only be used when the following
criteria are met: The Solar Blue is powered via
the power adapter. The Solar Blue is connected
to the computer via USB.
Module expected but not
connected
Contact your LABORIE
representative
Illegal use of LABORIE software on a network
Application cannot be started
from network location
Start application from
LABORIE database
Incorrect serial port selected. Blood pressure
recording not possible. Change serial port
settings and restart the test.
Incorrect serial port selected
Change serial port and
restart test
Invalid character encountered - use only hex
digits 0
…
9, A
…
F
Invalid character in catheter string
to decode
Contact your LABORIE
representative
Luna Cond not present
Luna channel expected but not
present
Contact your LABORIE
representative
Luna connection lost.
Communication problems
Contact your LABORIE
representative
Luna EMG not present
Luna channel expected but not
present
Contact your LABORIE
representative
Luna P1 not present
Luna channel expected but not
present
Contact your LABORIE
representative
Luna P2 not present
Luna channel expected but not
present
Contact your LABORIE
representative
Luna P3 not present
Luna channel expected but not
present
Contact your LABORIE
representative
MEMORY FULL **** DATA IS NOT SAVED NOW! Memory full, Investigation took
longer than expected
Stop the investigation
and start a new
investigation if
applicable
Содержание Nexam Pro CIM
Страница 1: ...Nexam Pro User Manual...