2NL/2P8
1-4-96
(2-6) U011XX error code table: G3 reception
Error code
Description
U01100
Function of the unit differs from that indicated by a DCS signal.
U01101
Function of the unit (excl. communication mode select) differs from that indicated by an
NSS signal.
U01102
A DTC (NSC) signal was received when no transmission data was in the unit.
U01110
No response after transmission of a DIS signal.
U01111
No response after transmission of a DTC (NSC) signal.
U01112
No training reception after reception of a DCS or NSS signal.
U01113
No response after transmission of an FTT signal.
U01114
No message reception after transmission of a CFR signal.
U01115
No message reception after transmission of an MCF signal.
U01116
No message reception after transmission of a PPR signal.
U01117
No message reception after transmission of a CTR signal.
U01118
No message reception after transmission of an ERR signal.
U01119
No further signals were received after reception of a message.
U01120
No response after transmission of an MCF signal.
U01121
No response after transmission of an RTP signal.
U01122
No response after transmission of an RTN signal.
U01123
No response after transmission of a PIP signal.
U01124
No response after transmission of a PIN signal.
U01125
No response after transmission of a CNS signal (between units of our make).
U01126
No response after transmission of a PPR signal (ECM).
U01127
No response after transmission of an ERR signal (ECM).
U01128
No response after transmission of an RNR signal (ECM).
U01129
No response after transmission of an SPA signal (short protocol).
U01140
A DCN signal was received after transmission of a DIS signal.
U01141
A DCN signal was received after transmission of a DTC signal.
U01142
A DCN signal was received after transmission of a DCS or NSS signal.
U01143
A DCN signal was received after transmission of an FTT signal.
U01144
A DCN signal was received after transmission of a CFR signal.
U01145
A DCN signal was received after reception of a message.
U01146
A DCN signal was received after transmission of an MCF signal (interoffice communica-
tion after reception of an MPS, EOM signal or confidential interoffice communication).
U01147
A DCN signal was received after transmission of an RTP signal.
U01148
A DCN signal was received after transmission of an RTN signal.
U01149
A DCN signal was received after transmission of a PIP signal.
U01150
A DCN signal was received after transmission of a PIN signal.
U01151
A DCN signal was received after transmission of a PPR signal (ECM).
Содержание TASKalfa 3010i
Страница 1: ...SERVICE MANUAL Published in September 2016 842NL11B 2NLSM06B Rev B TASKalfa 3010i TASKalfa 3510i ...
Страница 10: ...This page is intentionally left blank ...
Страница 100: ...2NL 2P8 1 2 76 This page is intentionally left blank ...
Страница 286: ...2NL 2P8 1 3 186 This page is intentionally left blank ...
Страница 443: ...2NL 2P8 1 5 59 This page is intentionally left blank ...
Страница 463: ...2NL 2P8 2 1 18 Figure 2 1 23 Duplex conveying section block diagram EPWB DU_SENS DU_CL_REM YC14 5 YC8 1 DUCL DUS ...
Страница 471: ...2NL 2P8 2 2 8 This page is intentionally left blank ...
Страница 532: ...Installation Guide DP 770 B Document processor DP 772 Document processor Installation Guide ...
Страница 568: ...DP 773 Document processor Installation Guide ...
Страница 594: ...PF 791 500 x 2 Paper feeder Installation Guide ...
Страница 602: ...PF 810 3000 sheet deck Installation Guide ...
Страница 615: ...DF 791 3000 sheet finisher Installation Guide ...
Страница 630: ...DF 770 D 1000 sheet finisher Installation Guide ...
Страница 648: ...AK 740 Bridge unit Installation Guide ...
Страница 650: ...MT 730 B Mailbox Installation Guide ...
Страница 665: ...PH 7A C D Punch unit Installation Guide ...
Страница 686: ...DT 730 B Document tray Installation Guide ...
Страница 731: ...5 2013 5 302LC56750 01 H F G D D 6 4 3 7 E C D D M4 8 M4 8 M4 8 M4 8 ...
Страница 732: ...FAX System W B Installation Guide ...