6.2018
29
5.1.2.1 Setting the temperature correction of heated water
By changing the value of the parameter
Correction
you can adjust the calculated temperature of
heating water in transitional (autumn and spring) periods and thus adjust the desired comfort in the
heated building. You perform the settings in the following steps:
1.
Press key
(MENU) in the basic menu.
2.
The first line has the parameter
Heating
selected. To set the parameter press key
(ENTER).
3.
Choose the
Correction
parameter by pressing
and press the
(ENTER) key.
4.
* * appear along the chosen parameter.
The
keys
and
change the value of the
parameter
Correction
. The temperature can be
raised for no more than 15 K (°C).
For returning to the basic view press the key
(MENU) twice.
5.1.2.2
Setting the heating curve temperature -
Normal
By setting the parameter
Normal
you set the maximum heating water temperature at an outside air
temperature of -18 °C.
NOTE
After start-up of the device there is usually no need to change the parameter
Normal
in the menu
Heating
, except in cases of constructional changes in the heating system.
You perform the settings in the following steps:
1.
Press key
(MENU) in the basic menu.
2.
The first line has the parameter
Heating
selected. To set the parameter press key
(ENTER).
3.
Choose the
parameter
Normal
by pressing
and press the
(ENTER) key.
Standby…………………
Heating
35.5°C
Return 32.3°C
DHW 49.0°C
> Heating
<
1. Circuit
2. Circuit
3. Circuit
Comfort
2.0°C
Hysteresis
3.0°C
Heating Curve
>Correction
5.0°C<
Comfort
2.0°C
Hysteresis
3.0°C
Heating Curve
*Correction
5.0°C*
Standby…………………
Heating 35.5°C
Return 32.3°C
DHW 49.0°C
> Heating
<
1. Circuit
2. Circuit
3. Circuit
C/W I
Schedule
>Normal
35.5°C <
Eco
-2.0°C