24
6.2018
2.
In the user menu choose the menu
Additional
source
with the key
and press the key
(ENTER).
3.
In the menu
Additional source
choose
AddSourceOnly
NO
with the key
and
press the key
(ENTER).
4.
* * appear along the chosen parameter.
Use
the key
to change the value of the
parameter to
Only add. source YES
. Only the
source will run.
To confirm the settings press key
(ENTER).
5.
For returning to the basic view press the key
(MENU) twice.
6.
In the first row, after switching on the Backup
source, the main display will display the
information about the status of the device
Heating -
AddSourceOnly
-.
NOTE
The device in this mode can heat the heating and DHW.
The heating water will heat to the temperature set in the basic menu
Heating,
1. Circuit, 2. Circuit, 3. Circuit,
and
4.
Circuit.
In the case of a Frost
Protection program (
FP prog)
error the temperature of heating water will heat
up to the set temperature with the parameter
AntiFreeze
in the menu
AddSourceOnly
.
The DHW will heat up to the temperature set with the parameter
DHW
in the
menu
Additional source.
.
As soon as heating with the device will be made possible again, set the parameter to
AddSourceOnly NO
.
>
Additional source
<
Mode
Temperatures
Delay
OFF
Mode
PARALLEL
Rise for
5.0°C
>AddSourceOnly
NO<
Delay
OFF
Mode
PARALLEL
Rise for
5.0°C
* AddSourceOnly
NO*
Delay
OFF
Mode
PARALLEL
Rise for
5.0°C
> AddSourceOnly
YES<
Heating - AddSourceOnly -
Heating
►
40 °C
Return
32.3°C
DHW
49.0°C
Содержание WPG 30