6.2018
17
4.1.3 Setting the room temperature with a room thermostat
For setting the room temperature with a room thermostat consult the manual which come with the
thermostat or consult the installer.
NOTE
In case the thermostat is turned on all this time and the heating system does not
heat/cool the space to the desired temperature, check the settings of temperatures of
the heating system on the device.
NOTE
For choosing the function of heating or cooling an appropriate thermostat has to be
installed which allows both functions.
NOTE
For maintaining the correct operation of the heating system you have to choose a
suitable operating mode - winter (heating and DHW) or summer (DHW and cooling -
only in certain models). For choosing the mode see chapter 4.4.
4.2 Setting the temperature of heating water
Upon start-up the control of the heating water temperature of your heating system was set to
Heating curve mode
which ensures the most energy efficient operation of the device. In case the
automatically calculated temperature of the heating water (in accordance with the external
temperature) is insufficient for ensuring the comfort of living in the rooms, the temperature of the
heated water can quickly be raised or lowered by changing the parameter of cooler/hotter (
C/W
).
The values of the parameter
C/W
are adjusted in the menus
1.
Circuit 2. Circuit 3. Circuit or
4. Circuit
depending on which temperature you want to change. If you want to change (raise/lower)
the temperature of the heated water for the whole building or heating system, change the parameter
C/W
in the menu
Heating.
NOTE
Upon start-up the heating water temperature control was set to
Heating curve mode.
The authorised contractor for commissioning noted your heating water settings of the
heating circuits into chapter 11.
By setting the parameter
C/W
you set the number of temperature steps (one temperature step
equals 1 °C) for which you want to raise or lower the temperature of heated water. You perform the
settings in the following steps:
1.
Press key
(MENU) in the basic menu.
2.
In the user interface, use the key
and
choose menu 1.
Circuit
and press the key
(ENTER).
Standby………………………………
Heating
35.5°C
Return
32.3°C
DHW
49.0°C
Heating
> 1. Circuit <
2. Circuit
3. Circuit