Min. Temp.
40.0
20.0…70.0
The minimal temperature up to which the
alternative source will heat the DHW.
---Common---
Prior. DWH
YES
By choosing the parameter
YES
heating of
the DHW will begin first, followed by heating.
Cooling
100.0
100.0…120.0
Temp. of the alternative source above which
cooling is performed.
Cooled for
5.0
1.0…5.0
By how many °C to cool the backup source.
Dif. Min.
5.0
0.0…15.0
The min. difference between the temperature
of the alternative source and the temp. of the
buffer tank or temp. of the DHW for heating to
continue.
Protection
100.0
100.0…130.0
Setting the temperature for activating the
signal which the users lowering the
temperature of the alternative source can be
connected to.
DHW from
alternat.
ALT
Heating the DHW directly from the alternative
source or the buffer tank [
ALT,CON
].
ADDITIONAL
SOURCE
Parameter name
Adjustable
value
Scope
Parameter description
Switch to
Need
Mode of turning on the alternative source
[
Never, Need
or
constant]
.
Bi-point
–
7.0
-30.0…40.0
Bivalent point. Set outside temperature at
which the additional source is activated.
Delay
30
0… 300
[
0…180
] Start-up delay for the additional
source despite reached bivalent point.
Mode
PARALLEL
[
PARALLEL, ALTERNATIVE
] Mode of
additional source operation.
Raise for
5.0
0.0…20.0
Raising the heating temperature with
auxiliary operation.
AddSourceOnly
NO
By changing the parameter from
NO
to
YES
you
can turn on the operation of the backup
source (flow el. Heater) in case of a
malfunction of the cooling part of the device.
DHW
45.0
10.0…50
Turn on/off and temperature settings of DHW
heating with the backup source.
AntiFreeze
25
10.0…60.0
The antifreeze programme maintains the
temperature in the system using the backup
source in case of a malfunction of the device.
This is not true for the TZ malfunction (this
temperature is adjustable).
Remote switch
OFF
Turning on the additional source with remote
turn-off.
-Prot.w.AddSource-
Protection the heating system with a backup
source.
AS-on under
18.0
10.0…50.0
Turning on the additional source under x °C
of the return.
AS-off abov
20.0
10.0…50.0
Turning off the additional source above x °C
of the return.
Delay
300
0… 999
Delay of the turning on of the supply pipe.
Immt. under
–
10.0
25.0… 60.0
Direct turn on of additional source under this
temperature.
Hys.DHW2
5.0
1.0… 10.0
Temperature difference of standby.
Immt. under
–
10.0
-20.0… 0.0
Direct activation of additional source under
this temperature.
AS at DHW
NO
Outside the compressor operating range, a
flow electric heater is activated to achieve
higher DHW temperatures.
MODE
Parameter name
Adjustable
value
Scope
Parameter description
Mode
Winter
Changing the operating mode [Summer,
AUTO,
Winter
]. For a detailed explanation
see chapter 4.4.